Montage Installation
LUBING Top Klima System - 20 - LUBING Top Climate System
Storing and Restoring
When the system is not in use for exaple in win-
tertime drain the water out of the pipes. To do
that open the valves at the end of each nozzle
line and/or unmount the mechanical drain
valves.
Important: In frosty climates the pump has to
be waterfree also.
Before each restoring of the system clean the
pipes very thorough. Then close the valves.
Important: Clean the plant in the same way in
intervalles, latest at the beginning of a new sea-
son.
Important: Also check the tension belt in inter-
valles an correct if nessesary. Therefor the
pump can be justated. Take care of the straight
line of the pulleys.
The indications for starting please look at "Func-
tion of the control unit".
Disinfecting
Disinfecting with the LUBING top climate system
is in normal possible. Just remember some ad-
vises:
Normal disinfections* can be used up to 1%
concentration in maximum. To put these dis-
infections into the system just use the
LUBING medicator. It has to be mounted in-
to the suctions line of the pump (in front of
the filters).
The disinfection must be totally liquid in the
water, there should be no crystals, because
they will damage the pump and the nozzles.
After disinfecting the whole system must be
flushes with fresh water, to clean pump,
nozzles and lines. To clean even the noz-
zles the ball valves at the end of each line
should be close.
* A list with all normal disinfections can be or-
derd at „Deutschen Veterinärmedizinischen Ge-
sellschaft (DVG) für den Lebensmittelbereich“
(Frankfurter Str. 89, 35392 Gießen, -
http://www.dvg.net)
Except for chlorine-based disinfectants, as this
may cause damage to components of the sys-
tem.