DACS II/Rel 8.2.6 April 2000
2-15
DACS II/Rel 8.2.6
MML
RLS,LPBK,T1,E1
26151
/* [O.26151.01] */
/* <explanation of error condition code> */
;
Explanation of
Parameters
LPBK
Loopback
loop
Loopback type
loop Explanation
LINE
Line
PYLD
Payload
NOTE:
loop=PAYLD is not valid for TE and TH type NPCs.
1.544 Mbit/s Termination
t
Loopback signal transmission specifier
value
Explanation
N
Do not send AIS downstream
For TE and TH type NPCs on an HDS3U, AIS is sent
downstream as a default.
1.544 and 2.048 Mbit/s Termination
NPC
Network processing circuit
[s]abc
The 3- or 4-digit nonhierarchical NPC number
The valid values are in chapter 2, except that for TH type NPCs
that carry E1s within a Hybrid DS3U all NPC numbers that are
divisible by 4 as well as all NPC numbers that end with a "D" or
"H" are invalid.
For a listing of the nonhierarchical numbering scheme, refer
to Chapter 2, "NPC Numbering and XYZ Parameters."
uv-m-np
Hierarchical NPC number
uv
Unit number
m
Module number
np
NPC number within the module
The valid values are in chapter 2, except that for TH type NPCs
that carry E1s within a Hybrid DS3U all NPC numbers that are