EasyManuals Logo

Lucent Technologies DACS II User Manual

Lucent Technologies DACS II
62 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #32 background imageLoading...
Page #32 background image
2-16
DACS II/Rel 8.2.6 April 2000
DACS II/Rel 8.2.6
MML
RLS,LPBK,T1,E1
26151
divisible by 4 as well as all NPC numbers that end with a "D" or
"H" are invalid.
For a listing of the hierarchical numbering scheme, refer
to Chapter 2, "NPC Numbering and XYZ Parameters."
LOCN
Location
locn
Loopback Location
locn Explanation
NEND
Near-end
FEND
Far-end
mmmm
Error condition code
mmmm
Explanation
ENEQ
Subject entity is not equipped
SAOS
Subject entity is out of service
ENEQ
Unit is not equipped
SAOS
UC is out of service
SNVS
UC is in service but failed
ENEQ
FTMI is not equipped
SAOS
FTMI is out of service
SNVS
NPC type error
ENEQ
The MXR is not grown
SAOS
MXR is out of service
IPNV
Invalid parameter combination
SNVS
Another signal already active prevents this
signal from being sent
SAOP
This signal is already being sent
SNVS
No signals active
IPNV
NPC is non-channelized
IPNV
NPC number out of range