2-34
DACS II/Rel 8.2.6 April 2000
DACS II/Rel 8.2.6
MML
RTRV,STATE,EQPT,NPC,LPBK
53131
The parameter value for NPC bb is just before EOM or COMPL.
wx-k-aa
Lowest numbered NPC in the FTM that contains NPC wx-k-qr
The parameter value for NPC aa is in the first position, first line
of the message.
wx-k-bb
Highest numbered NPC in the FTM that contains NPC wx-k-qr
The parameter value for NPC bb is just before EOM or COMPL.
For FTMs in FTUs or IFTUs, each row contains 10 values of
output.
For FTMs within DS3Us each row contains 7 values.
For FTMs within HDS3Us each row contains 4 values.
uv,wx
Unit number
m,k
Module number
np,qr,
aa,bb
NPC number within the module
The valid values are:
DA type NPC numbers listed by unit, module, and NPC Number
Unit Type FT (FTU)
TA NPC numbers listed by unit, module, and NPC Number
Unit Type DT (DS3U)
TE NPC numbers listed by unit, module, and NPC Number
Unit Type HT (HDS3U)
Unit Module NPC
1 - 16 1 - 40 1 - 40
Unit Module NPC
01 - 16 1 - 6 01 - 28
Unit Module NPC
01 - 16 1 - 6 01 - 28