Operating Manual Compact Weather Station
14 G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
6.5 Wet Bulb Temperature
Sampling rate 1 minute
Units °C; °F
Request channels:
UMB-Kanal
Measuring Range
act
Measurement Variable (float)
min
max
unit
114
WetBulbTemperature
-50.0
60.0
°C
119
WetBulbTemperature
-58.0
140.0
°F
6.6 Specific Enthalpy
Sampling rate 1 minute
Unit kJ/kg
Request channels:
UMB-Kanal
Measuring Range
act
Measurement Variable (float)
min
max
unit
215
SpecificEnthalpy
-100.0
1000.0
kJ/kg
6.7 Air Density
Sampling rate 1 minute
Unit kg/m³
Request channels:
UMB-Kanal
Measuring Range
act
Measurement Variable (float)
min
max
unit
310
Air Density
0.0
3.0
kg/m³