EasyManua.ls Logo

Lufft WS600-UMB - Page 76

Default Icon
104 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operating Manual Compact Weather Station
76 G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
18.6.4.7 Buffer Assignment Basic Data Set WS301-UMB
Device configured for measurement in metric units:
Measurement Value
UMB
Channel
Min
Max
Unit
Puffer ‘0’
Air Temperature (act)
100
-50.0
60.0
°C
Rel. Humidity (act)
200
0.0
100.0
%
Dew Point (act)
110
-50.0
60.0
°C
Global Radiation(act)
900
0.0
1400.0
W/m²
Rel. Air Pressure (act)
305
300.0
1200.0
hPa
Puffer ‘1’
Air Temperature (min)
120
-50.0
60.0
°C
Air Temperature (max)
140
-50.0
60.0
°C
Air Temperature (avg)
160
-50.0
60.0
°C
Rel. Humidity (avg)
260
0.0
100.0
%
Puffer ‘2’
Rel. Humidity (min)
220
0.0
100,0
%
Rel. Humidity (max)
240
0.0
100,0
%
Rel. Air Pressure (min)
325
300.0
1200.0
hPa
Rel. Air Pressure (max)
345
300.0
1200.0
hPa
Rel. Air Pressure (avg)
365
300.0
1200.0
hPa
Puffer ‘3’
Abs. Humidity (act)
205
0.0
1000.0
g/m³
Wet Bulb Temperature (act)
114
-50.0
60.0
°C
Specific Enthalpy (act)
215
-100.0
1000.0
kJ/kg
Puffer ‘4’
Global Radiation (min)
920
0.0
1400.0
W/m²
Global Radiation (max)
940
0.0
1400.0
W/m²
Global Radiation (avg)
960
0.0
1400.0
W/m²
Example: Request buffer ‘0’
0D0!
0+13.5+85.7+11.2+1017.0+780.0
Air temperature 13,5°C, rel. humidity 85,7%, dew point 11,2°C, rel. air pressure 1017hPa, global radiation 780W/m²