IS 5 · IGA 5
IS 5-LO · IGA 5-LO
INFRATHERM-Pyrometer
IMPAC - Spezialist für berührungslose Temperaturmessung
IMPAC - S
p
ecialist in non-contact thermometr
y
Betriebsanleitung · User Manual

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the LumaSense Impac IGA 5 and is the answer not in the manual?

LumaSense Impac IGA 5 Specifications

General IconGeneral
Optical Resolution150:1
Power Supply24 V DC
Storage Temperature-20 to 70 °C
Protection ClassIP65
Temperature Range250 to 2500 °C
Accuracy±(0.3 % of reading + 1 °C)
Repeatability±(0.1 % of reading + 1 °C)
Output0/4 to 20 mA, RS232, RS485
InterfaceRS232 / RS485
Operating Temperature0 to 50°C
Spectral Range1.45 to 1.8 µm
Emissivity Adjustment0.100 to 1.000 (adjustable via keys or software)
SightingThrough-lens sighting or laser sighting (switchable)

Summary

Technical Data

Safety Precautions

Laser Targeting Light Safety

Details safety precautions regarding the laser targeting light, its class, and warnings.

Electrical Connection Safety

Outlines safety regulations for mains voltage connection and qualified personnel.

Electrical Installation

Pyrometer Connector Pinout

Details the pinout of the pyrometer's connector for various functions.

PC Connection (RS232/RS485)

Explains how to connect the pyrometer to a PC via RS232 or RS485 interfaces.

Instrument Alignment

Optics and Optical Heads

Spot Sizes vs. Measuring Distance

Provides tables showing spot sizes for different distances and optics.

Instrument Settings

Instrument Settings Summary

Provides an overview of the DIP switch functions for various settings.

Operating Mode: Online/Offline

Explains the function of the online/offline switch for parameter settings.

Analog Output Configuration

Details how to set the analog output signal (0-20mA or 4-20mA) via DIP switch.

Exposure Time (t90) Adjustment

Explains how to adjust the exposure time using DIP switches for measurement stability.

Emissivity (ε) Settings

Explains emissivity and methods for determining and setting it for accurate readings.

Emissivity Values for Materials

Lists typical emissivity values for various materials across different spectral ranges.

Software Settings

Max Value Storage and Clear Times

Explains how to manage maximum value storage settings and clear intervals.

Interface and Software Settings

Connecting Pyrometer to PC

Explains how to connect pyrometers to a PC for software operation.

Basic Software Settings

Details how to display and modify pyrometer parameters within the software.

Integrated PID Controller

Explains the function, activation, and parameter setting of the integrated PID controller.

PID Self-Tuning Algorithm

Details the PID controller's self-tuning algorithm for automatic parameter determination.

Maintenance Procedures

Safety During Maintenance

Details safety precautions to be taken before performing maintenance on the pyrometer.

Troubleshooting Guide

Universal Pyrometer Protocol (UPP)

PID Controller Commands

Lists commands for controlling the integrated PID controller via interface.