EasyManua.ls Logo

LumaSense Impac IS 5 User Manual

Default Icon
31 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
IS 5 · IGA 5
IS 5-LO · IGA 5-LO
INFRATHERM-Pyrometer
IMPAC - Spezialist für berührungslose Temperaturmessung
IMPAC - S
p
ecialist in non-contact thermometr
y
Betriebsanleitung · User Manual

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the LumaSense Impac IS 5 and is the answer not in the manual?

LumaSense Impac IS 5 Specifications

General IconGeneral
Protection ClassIP65
Analog Output0/4 to 20 mA
Digital InterfaceRS-232
Power Supply24 V DC
Emissivity0.10 to 1.00 adjustable
SightingLaser aiming

Summary

2 Technical data

3 Safety

3.1 General

General safety advice for operating the pyrometer.

3.2 Laser targeting light

Safety precautions for the laser targeting light.

3.3 Electrical connection

Safety regulations for electrical connections and potential hazards.

4 Electrical Installation

4.1 Connector pin assignment on the back of the pyrometer

Detailed pinout for the pyrometer's connector.

4.2 Connecting the pyrometer to a PC

Details on connecting the pyrometer to a PC via RS232 or RS485.

6 Instrument alignment

6.2 Laser targeting light

Operating and safety instructions for the laser targeting light.

7 Optics / Optical heads

7.1 Spot sizes in relation to the measuring distance

Table showing spot sizes for different distances and optics.

8 Instrument settings

8.1 Controls and switches

Overview of the pyrometer's controls and DIP switches.

8.3 Analog output 0...20 4...20 mA (DIP switch nr. 3)

Setting the analog output signal (0-20 mA or 4-20 mA) via DIP switch.

8.1.1 Overview instrument settings

Mapping of DIP switches to instrument settings like exposure time and output.

8.4 Exposure time t90 (DIP switches nr. 1 + 2)

Configuring exposure time using DIP switches for measurement accuracy.

8.2 Operating mode online offline (DIP switch nr. 4)

How to select between online and offline operating modes using DIP switch 4.

8.5 Emissivity (ε)

Adjusting emissivity for accurate temperature measurements.

8 Instrument settings

8.5.1 Emissivities of common materials

Table of emissivity values for various common materials.

9 Software settings

10 Settings via interface and software

10.7 Basic settings

Details on setting basic parameters like range, material, and temperature units.

10.8.1 The PID controller

Configuration and operation of the integrated PID controller.

10.8.2 Self tuning algorithm

Using the self-tuning algorithm to optimize PID controller parameters.

12 Maintenance

12.1 Safety

Safety precautions to be observed during pyrometer servicing.

13 Trouble shooting

14 Data format UPP® (Universal Pyrometer Protocol)

14 Data format UPP® (Universal Pyrometer Protocol)

Related product manuals