3.3 Test function
Press the T S-Unit, the controller will turn on
load for 30s. During daytime, the testing function can help
users to verify correct installation or for system trouble
shooting. 30s later the load will automatically turn off.
" est" key of
"Test press times
1
2
3
4
5
6
"
Output power
Set Dimming1
Set Dimming2
Set Dimming3
Set Dimming4
Set Dimming5
End of test function
Solar charge controller Smart-DC series User Manual
!
Password only applies to SG-Unit.
Num
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
Factor y Default
4H
100%
0H
100%
0H
100%
0H
0%
0H
100%
5.0V
0m
0.3A
Yes
12.2V
8%
Li
14.4V
13.8V
10.0V
11.0V
Yes
10s
10%
0000
Name
Time1
Dim1
Time2
Dim2
Time3
Dim3
Time4
Dim4
Time5
Dim5
D/N Thr
D/N Dly
Load I
Dim Auto
Dim V
Dim %
Battery
CVT
CVR
LVD
LVR
0℃ Chg
Delay off
Dim NP
Password
3.2 Read the parameters
Press the "Parameter" key of the S-unit to read the
setting parameters of the controller.
4.Starting up the controller
4
.1 Sel
f T
es
t
A
s s
oo
n as t
h
e c
o
n
t
r
o
lle
r i
s p
ow
er
e
d, it s
t
a
rts a s
e
lf t
e
st r
ou
t
ine
.
A
fter t
hi
s
, t
h
e LE
D disp
lay w
i
l
l c
ha
n
g
e t
o n
o
rma
l op
er
a
tion
.
Sy
s
t
em V
o
lt
a
ge
Th
e c
o
n
t
r
oll
e
r a
p
pl
i
e
s to L
i
thi
u
m, AG
M
, Liqu
i
d an
d G
el b
at
t
er
y
.
I
t i
s you
r r
e
s
po
ns
i
b
ilit
y to c
he
ck and e
n
s
ur
e t
ha
t th
ese s
e
t
tings
ar
e c
o
rrec
t f
or yo
ur bat
tery
, o
t
her
w
is
e the
y mu
s
t b
e a
m
end
ed.
S
M
R
-
DC is suit
a
b
l
e for l
it
h
ium b
a
ttery when i
t is se
t to L
i
t
h
ium
ba
t
t
er
y
, th
e c
h
ar
g
ing t
ar
g
et v
o
l
t
age a
n
d ch
ar
g
ing r
ec
ove
r
y
v
olt
a
ge can be set a
cc
o
rd
i
ng t
o c
us
to
me
r re
qu
i
rem
ents
.
The c
o
ntro
l
ler adj
u
st
s i
ts
e
lf a
uto
ma
t
ica
l
l
y t
o 1
2
V or 24
V syst
e
m
v
o
lta
g
e wh
e
n i
t i
s s
e
t t
o Ge
l
, Li
qu
i
d o
r A
G
M bat
t
er
y
. I
f the
bat
ter
y v
o
l
tag
e o
n s
t
a
rt
-
u
p i
s 0
V
-15
V th
en t
he c
o
n
tr
o
ller i
nfe
rs
a 1
2V s
y
s
tem. If t
he ba
t
tery v
o
ltag
e is 2
0
V-
3
0
V th
e c
on
tro
l
ler
inf
e
rs a 2
4
V sy
s
t
e
m
.I
f t
h
e b
a
t
tery v
o
ltage is n
o
t wi
th
i
n t
h
e
n
o
r
m
al op
e
r
ati
n
g ra
ng a
t start
-
up
, pl
e
ase re
f
er t
o F
a
ul
ts &
Al
a
rms
.
4
.2
4.3 0℃ Charging Protection(Lithium Battery)
"
0
℃ Chg"
can be set t
o
"Yes", "
Slow" or
"
No". When the
contr
oller detects that the ambient t
emperatur
e is higher
than 0
℃,
the charging function is normal
. when the ambient
temperature is low than 0℃, if the "0
℃
Chg"
is set t
o "
Y
es",
the char
ging function is normal, else if the
"0
℃
Chg
"
is set
to "
slow
"
, the max char
ging curr
ent is 20% o
f the rat
ed
curr
ent, else if the "0
℃
Chg"
is set t
o "No", the contr
oller
does not char
ge the b
atter
y
.
The user can select the appr
opriat
e char
ging method.
For controllers with infrared sensing function( R series), if
work mode is set to Five-stage Night Mode or T0T
mode , "DelayOff and Dim NP work in Time3 and
Time4 .
"DelayOff" setting range: 10~150s.
" " "
" " " " " "
" "
5. Streetlight Function
5.1 Dusk to Dawn (D2D)
Dusk to Dawn(D2D)
Light on
Light off
D/N Thr
D/N Thr
Sunset
Sunrise
D/N Dly
If "Time1" is set to "D2D", the controller works in dusk to
dawn mode.
!
1.Smart-DC controller is set to D2D mode, the
corresponding dimming setting is still valid.
2. If "Time1" is set to D2D mode, "Time4" can not be set
to T0T mode.
5.2 Five-stage Night Mode , (Time3 Time4 can induction)
Time1
Time2 Time5Time3 Time4
Light on
Light off
D/N Thr
D/N Thr
Sunset
Sunrise
D/N Dly
You can set the Time 1-5 and Dim 1-5 with S/SG-Unit.
5.3T0T mode(Time3、T0T can induction)
D/N Thr
Time1
Time2
Time5
Time3 T0T
Light on
Light off
D/N Thr
Sunset
Sunrise
D/N Dly
If "Time4" of the S-Unit is set to "T0T", this mode is T0T mode.
* If "Time4" is set to "T0T", "Time1" can not set to D2D mode.
Induction function Parameter setting example:
Time1: 1.0H/100% Time2: 2.0H/80% Time3: 3.0H/60%
Time4: T0T/40% Time5: 2.0H/100%
DelayOff: 10s Dim NP: 10%
The controller works as follows:
After the arrival of the evening the first time the load is
lit for 1 hour (full power 100%), the second time the load
is lit for 2 hours (power 80%), the third time load light for
3 hours (when people is near the lamp then the load is
60% light, when people is away from the lamp the load is
60% * 10% light), and then the controller according to
the actual night time automatically calculate the length
of the fourth paragraph (when people is near the lamp
then the load is 40% light, when people is away from the
lamp the load is 40% * 10% light), the fifth time load
light 2 hours (full power 100%).
Page 2 of 7 pages