EasyManua.ls Logo

Lycomin 0-360 - Operating Conditions

Default Icon
171 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TEXTRON LYCOMING
OPERATOR'S
MANUAL
0-360 and ASSOCIATED MODELS
SECTION 3
OPERATING
CONDITIONS
(CONT.)
Fuel Max.
Cons. Oil Cons.
RPM HP
Gal./Hr. Qts./Hr.
*Ma .
Cyl. Head
Temp.
Operation
HIO-360-C
Series
Normal Rated 2900
Performance Cruise
(75% Rated) 2700
Economy
Cruise
(65% Rated) 2700
205 ----
.91
500°F.
(260°C.)
154
12.5 .52
500F. (260°C.)
133 10.5 .45 500F. (260°C.)
HIO-360-D Series
Normal Rated 3200
Performance Cruise
(75% Rated) 3200
Economy Cruise
(65% Rated) 3200
190
142
123
- .85
500°F. (260°C.)
12.0 .48
500F. (260°C.)
10.0 .41
500°F.
(260°C.)
HIO-360-E Series
Normal Rated 2900
Performance Cruise
(75%
Rated)
2700
Economy Cruise
(65%
Rated)
2700
190
142
123
-
.85 500°F.
(260°C.)
11.8
.47
500F. (260°C.)
10.0
.41 500°F.
(260°C.)
*
- At Bayonet Location
- For maximum
service
life of the engine
main-
tain cylinder head
temperature between 150°F.
and 400°F. during con-
tinuous operation.
Added May 1996
3-16A