CARE & USE/INSTALLATION
|
45
MAXIMUM RUNS FOR ALL
APPLIANCES ON SUPPLY LINE
Run Length
3/4” Pipe (in feet)
Max BTU for all
Appliances on line
10 360,000
20 245,000
30 198,000
40 169,000
50 150,000
60 135,000
70 123,000
80 115,000
MODEL-SPECIFIC BTU OUTPUTS & MAX. RUNS FOR APPLIANCES
MODEL-SPECIFIC BTU OUTPUTS
MODEL CERAMIC BURNER (Btu) ROTISSERIE (Btu) TRIDENT ™(Btu) TOTAL INPUT
L27R 2 @ 25,000 1 @ 14,000 64,000 Btu/Hr
L27TR(F) 1 @ 25,000 1 @ 14,000 1 @ 21,000 62,000 Btu/Hr
L30R(F) 2 @ 25,000 1 @ 14,000 64,000 Btu/Hr
L30TR(F) 1 @ 25,000 1 @ 14,000 1 @ 21,000 62,000 Btu/Hr
L36R 3 @ 25,000 1 @ 14,000 89,000 Btu/Hr
L36TR(F) 2 @ 25,000 1 @ 14,000 1 @ 21,000 87,000 Btu/Hr
L42R 3 @ 25,000 1 @ 16,000 91,000 Btu/Hr
L42TR(F) 2 @ 25,000 1 @ 16,000 1 @ 21,000 89,000 Btu/Hr
L54TR(F) 3 @ 25,000 2 @ 14,000 1 @ 21,000 126,000 Btu/Hr