EM-7801-A Rev.7 P. 1 / 10
INSTRUCTION MANUAL
DC VOLTAGE/CURRENT INPUT MODULE, 4 points
(CC-Link V.1.10)
MODEL
R7C-SV4
BEFORE USE ....
Thank you for choosing M-System. Before use, please check
contents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact M-System’s Sales Office or representatives.
PACKAGE INCLUDES:
DC voltage/current input module .......................................(1)
Terminating resistor (110 Ω, 0.5 W) ...................................(1)
MODEL NO.
Confirm Model No. marking on the product to be exactly
what you ordered.
INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
POINTS OF CAUTION
NONINCENDIVE APPROVAL OPTION
This equipment is suitable for use in Class I, Division 2,
Groups A, B, C, D or Non-Hazardous Locations only.
WARNING! – Explosion Hazard –
Substitution of any component may impair suitability for
Class I, Division 2.
WARNING! – Explosion Hazard –
DO NOT disconnect while the circuit is live or unless the
area is known to be free of ignitable concentrations.
Temperature Code of this equipment is T5 and the Maxi-
mum Ambient Temperature is 55°C (Surrounding Tem-
perature inside the fire enclosure).
CONFORMITY WITH UL APPROVAL
This equipment is suitable for use in Installation Catego-
ry II and in a Pollution Degree 2 environment.
Altitude up to 2000 meters.
This equipment must be mounted inside a suitable fire
enclosure.
This equipment is to be supplied by a Class 2 power sup-
ply.
CONFORMITY WITH EU DIRECTIVES
The equipment must be mounted inside the instrument
panel of a metal enclosure.
The actual installation environments such as panel con-
figurations, connected devices, connected wires, may af-
fect the protection level of this unit when it is integrated
in a panel system. The user may have to review the CE
requirements in regard to the whole system and employ
additional protective measures to ensure the CE conform-
ity.
Install lightning surge protectors for those wires connect-
ed to remote locations. Choose a surge protector with its
maximum surge voltage 40V or less between lines. Rec-
ommended M-System model: MDP-D24.
POWER INPUT RATING & OPERATIONAL RANG
Locate the power input rating marked on the product and
confirm its operational range as indicated below:
24V DC rating: 24V ±10%, approx. 90mA
GENERAL PRECAUTIONS
Before you remove the unit or mount it, turn off the power
supply and input signal for safety.
DO NOT set the switches on the module while the power
is supplied. The switches are used only for maintenance
without the power.
ENVIRONMENT
Indoor use.
When heavy dust or metal particles are present in the
air, install the unit inside proper housing with sufficient
ventilation.
Do not install the unit where it is subjected to continuous
vibration. Do not subject the unit to physical impact.
Environmental temperature must be within -10 to +55°C
(14 to 131°F) with relative humidity within 30 to 90% RH
in order to ensure adequate life span and operation.
WIRING
Do not install cables close to noise sources (relay drive
cable, high frequency line, etc.).
Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
AND ....
The unit is designed to function as soon as power is sup-
plied, however, a warm up for 10 minutes is required for
satisfying complete performance described in the data
sheet.
056 222 38 18 mailbox@sentronic.com
www.sentronic.com
SEN
TRONIC AG

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the M-system R7C-SV4 and is the answer not in the manual?

M-system R7C-SV4 Specifications

General IconGeneral
BrandM-system
ModelR7C-SV4
CategoryI/O Systems
LanguageEnglish

Related product manuals