For commercial air conditioner products, such as cassette type air
conditioners, duct type air conditioners, ceiling & floor air condition-
ers and some floor-standing air conditioners, their operation mode
should be determined based on the difference between the indoor
temperature and the set temperature.
Indoor Temperature Operation Mode
Target
Temperature
Below T-3°C (3°F) HEATING T
T-3°C (3°F)<Tindoor<T+3°C
(3°F)
FAN ONLY
Over T+3°C (3°F) COOLING
T
T
Indoor Temperature Operation Mode
Target
Temperature
T+3°C (3°F) or below FAN ONLY
COOLING
T
TOver T+3°C (3°F)
The AUTO function does not run with the TURBO mode (only on
some models).
The ECO function does not run with the AUTO mode.
To cancel the AUTO mode, press the MODE pad.
Note: Temperature, airflow and direction are controlled automati-
cally in AUTO mode.
Heat Pump models
Cooling Only models