6. Technical parameter
Model
ECO90/
240MM
ECO130/
240MM
ECO160/240
MM
ECO200/
240MM
ECO240/
240MM
PERFORMANCE CONDITION: Air 27°C/ Water 27°C/ Humid. 80%
Heating capacity (kW)
9.0
13.0
16.1
20.4
24.4
COP Range
6.4~10.8
6.3~11.0
6.2~10.9
6.3~11.0
6.3~11.0
PERFORMANCE CONDITION: Air 15°C/ Water 26°C/ Humid. 70%
Heating capacity (kW)
6.5
9.0
11.0
14.0
16.0
COP Range
4.4~6.4
4.7~6.4
4.3~6.6
4.3~6.4
4.5~6.6
TECHNICAL SPECIFICATIONS
Operating air
temperature
()
-5~43
Rated input power
(kW)
0.28 ~ 1.55
0.41 ~ 2.01
0.50 ~ 2.56
0.60 ~ 3.26
0.72 ~ 3.81
Rated input current (A)
8
12.0
17.0
19.0
20.0
Sound level at 10m
dB(A)
21.6~33.5
23.9~34
26.2~37.3
26.3~38.1
26.9~38.7
Advised water flow
(L/min) ± 20%
50
75
90
120
150
Water connection
(mm)
40
Remarks:
This heat pump is able to perform normal within air temp -5°C
43°C, efficiency will not be guaranteed out
of this range. Please take into consideration that the pool heat pump performance and parameters are
different under various conditions.
Related parameters are subject to adjustment periodically for technical improvement without further notice.
For details, please refer to nameplate.