38
6. Parameters Table
NO.
Content
Adjust range
Step
length
Default
P0
Water pump running way
0Continuation
1Water temp control
2time/water temp control
1
2
P1
Time setting (only available when the water
pump running way is set to “2
10 ~ 120 min
5 min
60 min
P2
Compressor continuously running time in
defrosting mode
30 ~ 90min
1min
35 min
P3
Defrosting start temp
-17 ~ 0
1℃
-7℃
P4
Defrosting running time
1 ~ 12min
1min
12 min
P5
Defrosting quit temp
8 ~ 30
1℃
13
P6
Single pump option
On/off
0 ~ 100
1
off
P10
Compressor speed control
0Auto1Manual
1
0
P12
Electronic expansion valve overheat level
heating
-10 ~ 20
1
3
P13
Electronic expansion valve overheat level
cooling
-10 ~ 20
1
5
P14
Electronic expansion valve manual/auto
0Auto1Manual
1
0
P15
Electronic expansion valve opening setting
heating
50 ~ 240
2P
175H5
P16
Electronic expansion valve opening setting
cooling
50 ~ 240
2P
175H5
P20
Power off memory function
0 NO1 YES
1
1

Related product manuals