5.7 Cylinder bleeding
Non-liquefied gasses draining valve (33) is calibrated at 12.8 bar for the standard version
and for 16.8 bar for HD version; the valve was installed to allow gradual removal of non-
liquefied gasses from the external tank.
The valve is automatically energized by the system each time there is non-liquefied gas in
the tank and their pressure is greater than the calibration pressure.
The purpose of the non-liquefied gasses draining valve (33) is to allow gradual removal of
non-liquefied gasses present inside the internal tank if their pressure exceeds the
calibration pressure for 33 non-liquefied gasses draining valve.
.
33 NON-LIQUEFIED
GASSES DRAINING
VALVE