45-610 Displacer Type Liquid Level Switches and Proof-er
®
Switches
39
4.5 Model Numbers
 




    I,    
      I, 

Series O Snap Switch
300
SPDT OMB Not OWB OMN
(149)
DPDT OKB Available ONB OKN
Series Q Snap Switch
250
SPDT QMB QRB QWB QMN
(121)
DPDT QKB QLB QNB QKN

Pressure/temperature ratings on page 13. Flanges are ANSI type.
Not available with material of construction codes 4, M and N.
316 SS flange is provided with material of construction code 4
and M.
Pneumatic switch mechanisms and enclosures are unavailable for
Models C10 and C15 switches.
Process temperature based on +100 °F (+38 °C) ambient.
Consult factory for NEMA 4X/7/9 cast iron housings.
125# flanges will be cast iron.