Parameters General Explanation
200 series settings shown as example settings
DLY 02000 CYCLE START DELAY - Delay before cycle start. (milliseconds)
Time in milliseconds that the sensor must be uncovered before cycle start. Minimum
of 02000 (ms) is recommended. With low throughput, increasing DLY may allow
better mixing if needed.
DTI 00006 WEIGH BIN DUMP TIME at end of cycle. (Seconds)
Maximum TIME allowed to determine an empty weigh reading.
STL 00500 DISPENSE SETTLE TIME. (milliseconds)
Time for dispensed material to SETTLE before weighing.
SBO 00000 SENSOR BLOW OFF
If SBO is set to a value, the Weigh Scale Blender will pulse the FCV valve by a
specified pulse length and specified delay in between pulses for the purpose of
clearing dust and particles from the face of the sensor. The pulse length is set by
the value in the 1st digit of the SBO parameter. The 1st digit for pulse width is in .1
seconds (1/10
th
second intervals). After the pulse, there will be a delay to the next
pulse based on the value set in the last 2 digits of the SBO parameter. The last 2
digits for the pulse delay are in seconds. If the SBO parameter has been activated
by entering values, the pulses will operate for a maximum of 20 times as long as the
sensor remains covered. Recommended SBO parameter setting is 10030, which
would pulse a 1/10
th
second pulse every 30 seconds.
FUL 20000 FULL BATCH TARGET WEIGHT in Grams
Change only for extremely light or heavy material. Default values are based on
average material volume. Light weight material may exceed weigh bin volume and
may require lowering FUL value. Lowering FUL decreases throughput.
MAX 30000 Maximum BIN WEIGHT - weight the software will target (grams).
FUL is the target weight that is blended each cycle. Change only for extremely fluffy
or very heavy material. MAX prevents overflowing of the weigh bin. It is reset
automatically if the FUL parameter is changed.
TH 01000 Tare Weight High Limit
TL 00500 Tare Weight Low Limit
TH and TL are upper and lower limits for tare weight.
If tare weight is below the value of TL, the ALARM sounds.
If tare weight is above the value of TH, the ALARM sounds and the weight bin
opens, attempting to empty. Increase TH if material tends to stick to the weigh bin.
Default value is model dependent. Variations in tare weigh does not affect accuracy.
PRN 00000 Percent of Regrind to be Treated as Natural
1st digit: 0 = adds, 1 = subtracts ... additive to or from the regrind.
2nd digit: Regrind component.
3rd digit: 0 = all additives. Entering a number specifies that additive component only.
Last 2 digits: Percent of Regrind. 99 = 100.
Example: 01030 - 0=add, 1=Regrind in 1, 0=all additives, 30% of regrind as natural.
3rd digit should use 1-9, A, B, C for component numbers.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the MAGUIRE Weigh Scale Blender 4088 TSC and is the answer not in the manual?

MAGUIRE Weigh Scale Blender 4088 TSC Specifications

General IconGeneral
BrandMAGUIRE
ModelWeigh Scale Blender 4088 TSC
CategoryController
LanguageEnglish