6. System and product information
6.3 ER EC functions
change display (6 months) with TimeStrip ●
Filter change display (6 months) with LED
● ● ●
Controller with time module
● ● ●
Control with fully automatic humidity control: Extraction
takes place automatically if the specified switch
-on
.
●
Control with motion detector. Full load level
after motion is detected (range of motion of the motion
sensor is
5 m)
●
-free product, as the fan switches itself on
● ●
-controllable ● ● ● ●
Electrical plug connection for quick connection
of the ER EC with ER GH housing and ER
-AK, ER-AH
-AB with the ER EC fan insert.
● ● ●
– base load 30 m³/h for continuous operation ● ● ● ●
Air volume of the base load and full load levels can be set
● ● ●
Additional air volumes that can be set in base load: 20 m³/h,
40 m³/h and full load 100 m³/h
● ● ●
Full load level on/off via light switch or separate switch.
During manual operation (e.g.
using light switch), the start
delay and overrun time apply.
● ● ● ●
m³/h) with start delay of 60 seconds
minutes, non-adjustable
●
Full load operation (60 m³/h), start delay can be set with
60*, 90 or 120 seconds
● ● ●**
Overrun time of the full load level can be set for 0, 3, 6,
15*
● ● ●
Adjustable interval control for ventilating rooms that are not
regularly used. Time interval can be set for
0*, 1, 2, 4, 6 or
12 hours, 10 min. operating time per interval
● ● ●
Interval control can be switched off.
● ● ●
Switching option: The base
load can be switched on or off
● ● ● ●
* Factory setting: Tolerance of time details max. ± 5 %
** For the ER-B, the start delay only affects the light switch operation