Properties Limit Unit
1)
Dust (sand, cement, CaO, Al
2
O
3
etc.) max. 5 mg/Nm
3
Chlorine max. 1.5
Sulphur dioxide (SO
2
) max. 1.25
Hydrogen sulphide (H
2
S) max. 5
Salt (NaCl) max. 1
1)
One Nm
3
corresponds to one cubic meter of gas at 0 °C and 101.32 kPa.
Table 1: Typical values for intake air (combustion air) that must be complied with
Explosion caused by flammable intake air
Explosion caused by flammable intake air can result in severe injuries
and damage.
Intake air must not contain any flammable gases.
Intake air is not explosive.
Intake air is not drawn in from the ATEX Zone.
Quality guidelines (conventional and Common Rail
engines)
Quality guidelines (conventional and Common Rail engines)
General
2017-01-10 - de
010.000.023-17
MAN Diesel & Turbo
2 (2) D010.000.023-17-0001 EN