Pump module
Compressed air reservoir module
Urea storage tank
Urea storage tank minimum level switch
Piping
insulation
Standard operation
Common SCR systems provided by third parties
require constantly high exhaust gas temperatures.
The MAN Diesel & Turbo SCR system on the other
hand is an integrated engine + SCR system that
allows operation on lower exhaust gas temperature
levels.
The MAN Diesel & Turbo SCR system automatically
adjusts the engine exhaust gas temperature to
ensure both optimum engine + SCR operation. For
a maximum on safety the surveillance mode is
always activated.
Enhanced operation
The MAN Diesel & Turbo SCR system assures ideal
engine operation, regenerating the SCR system
whenever necessary to account for a minimum fuel
oil consumption while complying with IMO Tier III
emission limits at all times. Dependent on the ambi-
ent conditions it may be needed to adapt the
engine load during the regeneration phase.