141
ELECTRICITY
80
547379EN
80 (08/03/2017)
Led Message Message Description and
Investigations
Variable Speed
Controller
Hour meter Calibrator Comments
5 Flashs
FAULTS
SENSORS
C_OVL Ssr Flt This fault is detected when there is
a fault on the overload sensors.
- Check:
The status of the overload circuits.
The electrical circuit and connections.
• Basket electronic control unit and safety electronic control unit.
F02004 C_OVL Sync
Flt
This fault is detected when the
two overload sensors are not in
the same status.
- Check:
The status of the sensors: parameters: 1.3.16 and 2.4.9.
The overload settings.
The electronic control unit and connections of the sensors.
• Basket electronic control unit and safety electronic control unit.
F02005
ElvTd Ssr Fault
Signals an inconsistency between
the “working/travel” position
sensors (telescope or arm 2/3).
- Check:
The settings of the Working/Travel” position sensors.
The correct operation of the sensors.
The electronic control unit and connections of the sensors.
• Logic module of the variable speed controller and safety
electronic control unit.
F05010
Bypass pump
Fault switch KM3 stuck
- Check KM3 switch
6 Flashs
ACCELERATOR
F02001
Accel. Fault
Voltage fault in the joystick on one
of the X or Y axes.
Accelerator Value >20% on start-
up for one of the X or Y axes.
- Check:
That the joystick is activated when switched on.
The joystick supply voltage.
The values of the manipulator parameters for each of the X and
Y axes.
The conguration of the joystick potentiometer values.
That the gray (Y) and yellow (X) harnesses of the joystick and
their connections are in good condition.
F02000 Accel. Fault Accelerator fault (out of range). - Check the manipulator, its wiring.
7 Flashs
VOLTAGE
BATTERY
F04010 Battery High Battery voltage high
on “High V cut” parameter.
- Check the correct operation of the battery charger.
F04009 Battery Low Battery voltage higher than the
“High V cut” parameter.
Battery voltage lower than the
“Low V cut” parameter.
Battery voltage lower than the
“battery protection” parameter,
beyond the delay specied by the
parameter “protection delay”.
- Check:
The state of the battery charge (voltage, electrolyte density, water
level).
The correct operation of the battery charger, its connectors.
- Put the access platform on charge.
F01004 BDI Cutout Battery charge level lower than
“BDI CUTOUT” parameter.
- Check:
The battery electrolyte-specic gravity.
The condition of the battery cables.
The tightening of the cable terminals.
The BDI parameters.
- Put the access platform on charge.
8 Flashs
TEMPERATURE
F01005 Thermal
Cutback
The temperature of the power unit
is higher than 75°C (167 °F).
- Check:
The operating conditions (motor overload, etc.).
The tightening of the power terminals (motor, battery).
The tting of the variable speed controller plate on the chassis
(heat-conducting grease, etc.).
- Leave the variable speed controller to cool
9 Flashs
COIL
SWITCH
F05000
Coil s/c
The intensity of the current is
higher than the acceptable limit
for one of the following outputs:
- Coil of switch KM1.
- Relay.
- Electrovalves.
- LEDs.
- Buzzer.
- Harnesses.
- Check the current limit on the following digital inputs and outputs:
• 2A for the connector outputs of the variable speed controller
logic module (Plug 8 and 9 of connector B).
• 2A for the outputs of the connector “D-OUT of the CAN
electronic control unit of the BASE.
• 2A & 100 mA for the outputs of the connector “D-OUT of the
CAN electronic control unit of the BASKET.
F05022 Coil s/c (ext) Digital output in short circuit on
the E/S module: BASKET
- Check:
• The wiring.
The elements controlled by the module.