3 - 24
D7 HYDROSTATIC PUMP OIL FILTER TRANSMISSION
REPLACE
p
Risk of poisoning and injury!
Contact with hydraulic uid damages your health (e.g. eye injuries, skin and tissue damage, poisoning throu-
gh inhalation). While working with hazardous materials (for example, hydraulic uids), always wear safety
gloves and safety glasses.
Procedure
To replace the filter cartridge and the filter case seal:
- Loosen and remove the filter housing 4 from the filter head 1
- Remove the used filter cartridge 3 from the filter housing 4
- Check the filter head and filter housing for damage, wear and contaminants.
- Insert the new filter cartridge 3 into the filter housing 4
- Check the O-ring and O-ring groove for damage, wear or contaminants.
- Replace the O-ring 2 with a new one. Lightly grease the O-ring.
- Screw the filter housing 4 onto the filter head 1
- Tighten the filter housing 4 with a torque of 45 Nm.
D8 FORKS WEAR*
CHECK
Contact your dealer.