62 Part Number 040005626 5/17
Determining Which Safety Limit Stopped
the
Ice Machine:
1. Cycle the toggle switch Off.
2. Cycle the toggle switch On to start ice making.
3. Watch the safety limit lights.
One will flash corresponding to safety limits 1 or 2.
4. Safety limit 3 is indicated by both SL#1 & SL#2
flashing.
After safety limit indication, the ice machine will restart
and run until a safety limit is exceeded again.
Safety Limit Notes
A continuous run of 100 harvests automatically
erases the safety limit code.
The control board will store and indicate only one
safety limit – the last one exceeded.
If the toggle switch is cycled OFF and then ON
prior to reaching the 100-harvest point, the last
safety limit exceeded will be indicated.