EasyManua.ls Logo

Manitowoc RFF - Air-Cooled Condenser Cleaning; Removal from Service;Winterization; Water-Cooled Machine Winterization

Manitowoc RFF
164 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
28 Part Number 000015433_03 5/20
D. Hand descale the removed part(s) in a properly
mixed solution of descaler and water.
Solution Type Water Mixed With
Descaling 1 gal. (4 L) 16 oz (500 ml) Cleaner/Descaler
Part Number 000000084
E. Use a soft-bristle brush or sponge (NOT a wire
brush) to carefully clean the parts.
F. Use the solution and a brush or sponge to clean
all disassembled components and the inside of
the bin.
G. Rinse all cleaned parts with clear potable water.
H. Mix a solution of sanitizer and water.
Solution Type Water Mixed With
Sanitizer 3 gal. (11 L) 2 oz (60 ml) sanitizer
Part Number 94-0565-3
I. Use the sanitizer/water solution and a sponge to
sanitize all removed components and the inside
of the bin. Do not rinse the sanitized parts.
NOTE: Descale, rinse and spray sanitizer on all interior and
exterior areas of the evaporator discharge spout on UFF
and UNF models.

Table of Contents

Other manuals for Manitowoc RFF

Related product manuals