ELECTRICAL DIAGNOSTIC FLOWCHART
Power Supplied
to Ice Machine?
Toggle Switch In
ON Position?
Move Switch To ON Position
Restore Power, Reset BreakerNO
NO
YES
Electrical Flowchart - RF2300C/RFC2300& QuietQube
Switch
Illuminated?
NO
YES
Replace Switch
Immediately
Trips?
YES
YES
Toggle Switch In
Off Position?
Isolate And Ohm Each
Component - Then Each
Wire If Required
NO
TRIPS
YES
Isolate And Ohm Switch
Check Wiring From Panel
YES
NO
Test Run