Maintenance Section 4
4-10
Part Number 000000966 03/09
Multiple Evaporator Ice Machines
A. Remove panels
• Remove both front panels
• Remove top panel
B. Remove front evaporator shield.
• Remove four quarter turn connectors
• Remove splash shield
C. Remove left and right evaporator top covers.
• Remove two thumbscrews from the front of
each evaporator top cover.
• Lift front of cover, pull forward to remove.
D. Remove Splash Shields.
• Grasp the top center of splash shields.
• Lift up and then out.
NOTE: Each evaporator has a splash shield that must
be removed - total of four splash shields.
E. Remove ice thickness probe.
• Compress the hinge pin on the top of the ice
thickness probe.
• Pivot the ice thickness probe to disengage
one pin then the other. The ice thickness
probe can be cleaned at this point without
complete removal. If complete removal is
desired, disconnect the ice thickness control
wiring from the control board.
F. Remove distribution tubes.
• Distribution tube thumbscrews are retained to
prevent loss. Loosen thumbscrews but do not
pull thumbscrews out of distribution tube.
• Loosen the two outer screws and pull forward
on the distribution tube to release from slip
joint.
• Disassemble distribution tube by loosening
the two (2) middle thumbscrews and dividing
the distribution tube into two pieces.
NOTE: Each evaporator has a distribution tube that must
be removed - total of four distribution tubes.
G. Remove ice dampers.
• Grasp ice damper and apply pressure toward
the back mounting bracket.
• Apply pressure to the front mounting bracket
with thumb.
• Pull ice damper downward when the front ice
damper pin disengages.
NOTE: Each evaporator has an ice damper that must be
removed - total of four ice dampers
H. Remove the water pump assembly.
• Disconnect the vinyl distribution tube from
both water pumps.
• Disconnect the water pump and water level
probe electrical connections.
• After the wires are disconnected remove the
two thumbscrews and lift the water pump
assembly out of the ice machine.
• Remove the thumbscrews securing the water
pumps (2 each pump) and remove water
pumps. Do not immerse the water pump motor
in cleaner or sanitizer solutions.
• Remove the water level probe from the
assembly housing.
I. Remove the water trough.
• Pull forward on the water trough to remove.
NOTE: Proceed to page 4-12, Step 7.