SAFETY INFORMATION CD5515-2/YB5515-2 OPERATOR MANUAL
2-8 Published 1-20-2017, Control # 468-02
This 3-second wind gust is assumed to act on the entire
crane and the load. The wind effect on the load can be
conservatively estimated as:
a) If V(z) is 13.4 m/s (30 mph), then the allowable
load is the published rated capacity from the Load Chart.
b) If V(z) is > 13.4 m/s (30 mph) and is 20.1 m/s
(45 mph), the allowable load is the published rated
capacity multiplied by the Capacity Reduction Factor
from Table 2-4 (metric) or (non-metric).
NOTE: This condition is limited to operation with the main
boom on fully extended outriggers only.
c) If V(z) is > 20.1 m/s (45 mph), then lifting is NOT
permitted. Cease lifting operations and lower and retract
the boom.
In both cases a) and b) above, the lift may also be limited by
the projected wind area of the load Ap and by the wind drag
coefficient Cd: This limit can be determined by comparing
the Actual wind resistance area with the Allowable wind
resistance area.
Refer to Figure 2-2 for a simplified calculation method to
determine permissible wind speed.
Reference Only

Table of Contents

Other manuals for Manitowoc Shuttlelift CD5515-2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc Shuttlelift CD5515-2 and is the answer not in the manual?

Manitowoc Shuttlelift CD5515-2 Specifications

General IconGeneral
BrandManitowoc
ModelShuttlelift CD5515-2
CategoryConstruction Equipment
LanguageEnglish

Related product manuals