110 Part Number 000014797 Rev02 05/18


Possible Cause Checklist
Improper installation
• Refer to “Installation/Visual Inspection Checklist” on
page 100
Water System
• Dirty/defective water dump valve
• Low water float valve dirty or defective
• Vent tube not installed on water outlet drain
• Low water pressure (20 psig min.)
• Dirty defective water filter (when used)
• Loss of water from sump area
• Dirty/defective water inlet valve
Electrical system
• Water inlet valve coil defective
• Low water float valve defective

Table of Contents