62 Part Number 000014797 Rev02 05/18
Step 18 Mix a solution of sanitizer and warm water.
Solution Type Water Mixed With
Sanitizer 6 gal. (23 l) 4 oz (120 ml) sanitizer
Step 19 Use 1/2 of the sanitizer/water solution to
sanitize all removed components. Use a cloth or sponge to
liberally apply the solution to all surfaces of the removed
parts or soak the removed parts in the sanitizer/water
solution. Do not rinse parts after sanitizing.
Step 20 Use 1/2 of the sanitizer/water solution to
sanitize all foodzone surfaces of the ice machine and bin.
Use a cloth or sponge to liberally apply the solution. When
sanitizing, pay particular attention to the following areas:
Evaporator plastic parts - including top, bottom and
sides
Bin bottom, sides and top
Do not rinse the sanitized areas.
Step 21 Replace all removed components.
Step 22 Reapply power and water to the ice machine
and place the toggle switch in the ICE position.