Step 11 Use 1/2 of the sanitizer/water solution to
sanitize all removed components. Use a cloth or sponge to
liberally apply the solution to all surfaces of the removed
parts or soak the removed parts in the sanitizer/water
solution. Do not rinse parts after sanitizing.
Step 12 Use 1/2 of the sanitizer/water solution to
sanitize all foodzone surfaces of the ice machine and bin.
Use a cloth or sponge to liberally apply the solution. When
sanitizing, pay particular attention to the following areas:
Evaporator plastic parts - including top, bottom and
sides.
Bin bottom, sides and top.
Do not rinse the sanitized areas.
Step 13 Replace all removed components.
Step 14 Reapply power and water to the ice machine
and place the toggle switch in the WASH position.
Step 15 Add the proper amount of Manitowoc Ice
Machine Sanitizer to the water trough.
Model Amount of Sanitizer
UDE080 1.5 ounces (45 ml)
Step 16 Wait until the sanitize cycle is complete
(approximately 22 minutes) then place the toggle switch in
the OFF position, disconnect power and water supplies to
the ice machine.
n
Warning
Disconnect electric power to the ice machine at the
electric switch box before proceeding.
Step 17 Repeat step 6 to remove parts for hand
sanitizing.

Table of Contents

Other manuals for Manitowoc URF0140A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc URF0140A and is the answer not in the manual?

Manitowoc URF0140A Specifications

General IconGeneral
BrandManitowoc
ModelURF0140A
CategoryIce Maker
LanguageEnglish

Related product manuals