Comfort 250, 252
Operator System for Garages
Anriebssystem für Garagen
Anriebssystem für Garagen
Anriebssystem für Garagen
Anriebssystem für Garagen
Installation and Operating Instructions
Einbau- und Bedienungsanleitung
Einbau- und Bedienungsanleitung
Einbau- und Bedienungsanleitung
Einbau- und Bedienungsanleitung
GBGBFNLI
Question and Answer IconNeed help?

Do you have a question about the Marantec COMFORT 250 and is the answer not in the manual?

Summary

Meaning of Symbols

General Warning and Informational Symbols

Icons indicating safety warnings, material damage risks, functional checks, and general advice.

Control Unit and Operator Symbols

Icons representing operational states, components, and connections of the control unit and operator.

Important Safety Advice

General Safety Precautions for Installation and Operation

Crucial safety guidelines for qualified personnel, including electrical and mechanical safety.

Electrical Safety Warnings

Specific caution about power disconnection, safety time, and cable separation.

Operational and Mounting Safety

Advice on safe mounting, placement of warning signs, and preventing installation errors.

Installation Guide

Preparation and Required Tools

Steps for unpacking, listing necessary tools, and cautions for drilling.

Site Requirements and Mounting

Guidelines for suspending the motor unit and mounting it according to site needs.

Connecting Boom to Operator Unit

Detailed steps for securely attaching the boom to the operator unit.

Mounting Suspension Clamp to Boom

Instructions for attaching the suspension clamp to the boom for proper support.

Mounting Lintel Joining Plate

Securing the lintel joining plate to prevent unauthorized dismantling.

Unlocking the Carriage

Procedure to release and unlock the carriage for connecting to the door.

Installation for Up-and-Over Doors

Specific steps for installing the operator with up-and-over type garage doors.

Installation for Sectional Doors

Specific steps for installing the operator with sectional type garage doors.

Installation for Retractable Up-and-Over Doors

Instructions for retractable doors, including required accessories.

Fitting the Adapter Arm

Detailed instructions for fitting the adapter arm to the door structure.

Suspension of Operator System

Mounting the motor unit and boom suspension plates according to site requirements.

Installation of the Bulb

Procedure for safely installing the light bulb into the operator unit.

Quick Release Mechanism Operation

Instructions and warnings for operating the quick release mechanism.

Operational Check and Door Separation

Performing final operational checks and separating the door from the operator.

Hand Transmitter Operation and Programming

Hand Transmitter Operation and Accessories

Details on hand transmitter components, battery replacement, and fixing accessories.

Hand Transmitter Safety Precautions

Important warnings regarding safe operation of the hand transmitter and children.

Programming Hand Transmitter (Learn Coding)

Steps to transmit codes from an existing transmitter to a new one.

Changing Hand Transmitter Coding

Procedure for changing the coding if a hand transmitter is lost.

Control Unit Connections

Module Aerial Installation

Instructions for installing the module aerial for optimal signal reception.

Connecting External Control Elements

Wiring instructions for external control elements, buttons, and photocells.

Display Functions and Programming Possibilities

Meaning of LED Symbols

Explanation of the LED indicators on the control unit and their meanings.

Electronic Control Unit Summary

Overview of control unit functions, error messages, and LED indicators.

Error Messages and Troubleshooting

Guide on how to interpret error messages displayed by LED flashes.

Preparation for Programming

Prerequisites and conditions required before starting the programming process.

General Programming Advice

Important advice and guidelines for programming the operator functions.

Displaying Door Situations

Summary of display functions that indicate the current door status.

Programming Basic Functions Sequence

Step-by-step guide for programming the fundamental operator functions.

Setting Reference Point and Door Positions

Procedures for setting the reference point and door end positions.

Programming End Position OPEN

Setting the fully open position for the garage door.

Programming End Position CLOSE

Setting the fully closed position for the garage door.

Programming Remote Control

Process for pairing a hand transmitter with the operator unit.

Resetting Factory Settings

Instructions to restore the operator to its original factory default settings.

Learning Drive Power

The operator learns the force required for door movement.

Operational Test Procedures

Performing functional tests on the operator to ensure correct operation.

Overview of 2 nd Programming Level

Introduction to the extended operator functions available in the 2nd programming level.

Explanation of Extended Operator Functions (Menu 1-5)

Details on photocell, power limits, operator speed, and other advanced settings.

Configuring External Photocell

Setting up the operator to work with external photocell sensors.

Setting Automatic Cut-out for OPEN

Adjusting the sensitivity of the automatic cut-out for the opening direction.

Setting Automatic Cut-out for CLOSE

Adjusting the sensitivity of the automatic cut-out for the closing direction.

Setting Offset Learned Power Limit

Adjusting the offset for the learned power limit in OPEN and CLOSE directions.

Setting Operator Speed

Adjusting the operational speed of the garage door.

Adjustable Values of 2 nd Programming Level

Table summarizing the adjustable settings and values for the 2nd programming level.

Adjustable Values of 2 nd Programming Level (cont.)

Continuation of the table for adjustable settings in the 2nd programming level.

Explanation of 3 rd Programming Level (Automatic Timer)

Functions related to automatic closing, warning signals, and timer settings.

Setting Open Door Time

Configuring the duration for which the door remains open.

Setting Warning Time Before Closing

Configuring warning signals, such as flashing lights, before automatic closing.

Setting Warning Before Start

Configuring warning signals before the door begins its movement.

Setting Early Closing After Photocell

Configuring early closing behavior triggered by photocell detection.

Adjustable Values of 3 rd Programming Level

Table summarizing the adjustable settings and values for the 3rd programming level.

Adjustable Values of 3 rd Programming Level (cont.)

Continuation of the table for adjustable settings in the 3rd programming level.

Explanation of 4 th Programming Level

Functions for door travel time, soft stop, and intermediate positions.

Setting Excess Travel Stop Time

Configuring the maximum allowed door travel time.

Setting Soft Stop for Closing

Adjusting the soft stop feature for the door's closing movement.

Setting Intermediate Door Position

Defining a fixed partial opening position for the door.

Programming Remote for Intermediate Position

Assigning a remote button to activate the intermediate door position.

Adjustable Values of 4 th Programming Level

Table summarizing the adjustable settings and values for the 4th programming level.

Adjustable Values of 4 th Programming Level (cont.)

Continuation of the table for adjustable settings in the 4th programming level.

Explanation of 5 th Programming Level

Functions for light time, signal lights, external alarm relay, and 3-min. light.

Programming Light Time

Setting the duration for which the operator light remains active.

Programming Signal Lights

Configuring the behavior of external signal lights (permanent or flashing).

Programming Lighting Function

Setting the operator light behavior during warning periods.

Programming External Alarm Relay

Configuring the function of the external alarm relay.

Programming 3-min. Light; Signal Light

Setting the 3-minute light or signal light function.

Adjustable Values of 5 th Programming Level

Table summarizing the adjustable settings and values for the 5th programming level.

Adjustable Values of 5 th Programming Level (cont.)

Continuation of the table for adjustable settings in the 5th programming level.

Short Programming Instructions (Basic Functions)

Visual guide for quick programming of basic operator functions.

Short Programming Instructions (2 nd Level)

Visual guide for quick programming of extended operator functions (2nd level).

Short Programming Instructions (3 rd Level)

Visual guide for quick programming of extended operator functions (3rd level).

Short Programming Instructions (4 th Level)

Visual guide for quick programming of extended operator functions (4th level).

Short Programming Instructions (5 th Level)

Visual guide for quick programming of extended operator functions (5th level).

Cabling Plan Overview

Diagram and list of connections for the operator system components.

Wiring Diagram and Safety Notes

Detailed wiring diagram with important safety notes and warnings.

Test Instructions

Error Identification and Causes

Table listing common errors, their messages, and potential causes.

Troubleshooting Remedies

Solutions and actions to resolve identified errors and malfunctions.

Error Numbers

Error Number Visual Guide

Visual representation of error codes indicated by LED flashes on the control unit.

Initial Operation and Maintenance

Initial Operation Safety Checks

Safety checks required before initial operation and periodic inspection.

Maintenance Instructions and Safety During Work

Guidelines for regular maintenance and safety measures during repair or adjustment.

Technical Details

Garage Door Operator Specifications

Technical specifications including connected loads, door speed, forces, and protection category.

Manufacturers Declaration

Manufacturers Declaration of Conformity

Statement of compliance with EU directives in multiple languages.

Declaration of Conformity

EC Declaration of Conformity

Formal declaration of the product's conformity to relevant European directives.

Marantec COMFORT 250 Specifications

General IconGeneral
TypeGarage Door Opener
ModelCOMFORT 250
Motor typeDC motor
Voltage230 V
Frequency50 Hz
ControlRadio control
Safety Featuresobstacle detection