EasyManua.ls Logo

Mares GENIUS - 1. Introduction to the Genius Dive Computer; 1.1. Glossary of Diving and Technical Terms

Mares GENIUS
22 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
GENIUS Dive Computer
4
PART I
• 1. INTRODUCTION
1.1. GLOSSARY
AGF: Alternate gradient factor
AIR: Air dive
ASC:
Total ascent time, the time it takes to perform the ascent from your current depth to the surface in a decompression dive,
including all decompression stops and assuming an ascent rate of 10m/min or 33ft/min.
ASC + X: The overall ascent time inclusive of all decompression stops if the dive is extended by X minutes at the current depth.
AVG: Average depth, calculated from the beginning of the dive.
CNS: Central Nervous System. CNS% is used to quantify toxic effects of oxygen.
DESAT: Desaturation time. The time needed for the body to eliminate the nitrogen taken up during diving.
D-TIME: Dive time, the whole time spent below a depth of 1.2m/4ft.
Gas integration: The feature in Genius to include tank pressure information in its calculations and to display it on the computer screen.
Gas switching: The act of changing from one breathing gas to another.
GF: Gradient factor
Gradient Factor: Percentage of Bühlmann’s original value of maximum allowed supersaturation
Heliox: A breathing gas containing Oxygen and Helium.
Max depth: Maximum depth attained during the dive.
MOD:
Maximum Operating Depth. This is the depth at which the partial pressure of oxygen (ppO
2
) reaches the maximum allowed
level (ppO
2
max). Diving deeper than the MOD will expose the diver to unsafe ppO
2
levels.
Multigas: Refers to a dive in which more than one breathing gas is used (air and/or Nitrox).
Nitrox: A breathing mix made of oxygen and nitrogen, with the oxygen concentration being 22% or higher.
NO-FLY: Minimum amount of time the diver should wait before taking a plane.
No deco time:
This is the time that you can stay at the current depth and still make a direct ascent to the surface without having to perform
mandatory decompression stops.
O
2
: Oxygen.
O
2
%: Oxygen concentration used by the computer in all calculations.
Pairing: The act of establishing a coded RF communication between Genius and a dedicated device, such as a tank module.
ppO
2
:
Partial pressure of oxygen. This is the pressure of the oxygen in the breathing mix. It is a function of depth and oxygen
concentration. A ppO
2
higher than 1.6bar is considered dangerous.
ppO
2
max: The maximum allowed value for ppO
2
. Together with the oxygen concentration it defines the MOD.
Switch depth: The depth at which the diver plans to switch to a higher oxygen concentration mix while using the multigas option.
Trimix: A breathing gas containing Oxygen, Nitrogen and Helium.
TTR: Time To Reserve, it is the time that a diver can spend at the current depth before reaching the tank reserve.
SURF INT: Surface interval, the time that has elapsed since the end of the dive.
RGT:
Remaining Gas Time, it is the time that a diver can spend at the current depth before having to ascend in order to reach the
surface with the tank reserve still available.

Related product manuals