NOTE: Installation must be in compliance with the National Electrical Code and your local
electrical and plumbing codes.
1. Do not instal I the unit in a room where there is a chance of freezing.
2. DO NOT install this water heater near tinder, volatile or ammable substances, or
near a strong magnetic eld. The unit must only be mounted in a VERTICAL position
near the water ttings.
3. Mount the unit to a at section of walI, welI away from any potential water splashes
or spray. Be sure to use wall anchors, or screw directly into studs.
4. Position the unit upright with all plumbing connections at the bottom of the unit.
5. Make sure the water heater and all ttings are complete and intact.
6. Make sure that the main power supply, water pressure, ground, amperage, voltage,
and wiring meet all standards.
7. The water heater must be connected to a properly-grounded, dedicated branch
circuit with the proper voltage rating. The ground must be connected to the "ground
bar" at the circuit breaker panel.
8. This water heater MUST be permanently connected to xed and dedicated circuit
breakers.
If the heater will be unused, switch o the circuit breakers.
INSTALLATION
Locate an appropriate place on a section of wall that meets all safety and installation
requirements.
Front and back of the appliance (please see Fig. 07).
INSTALLATION GUIDELINES
11