Check for damage upon delivery and acknowledge with transporter for insurance claims.
Packaging is minimized, recyclable; disposal or return costs are recipient's responsibility.
Fasten the FBA device to the ceiling using approved fasteners, considering gear weights.
Mount accessories on the suction side using an intermediate frame and specific connection methods.
Mount roof accessories like raincovers or channels on-site; slabs are not included.
Adjust louvres with the unit off, ensuring devices are at 2.5m height for safety.
Attach heating supply lines to the heat exchanger, use a gate valve for maintenance.
Mount air valve at the highest point and drain valve at the lowest point for complete emptying.
Wiring diagrams for parallel connection of FBA devices using different switching units.
Wiring diagrams for isolator switches for different engine types (001 and 003).
Table detailing the maximum number of FBA devices connectable to various switchgear models.
Diagrams for 2-speed and automatic switching points for 400V engines.
Diagrams for 5-speed switching devices for 400V and 230V engines.
Diagrams for switchgear with servomotors, actuators, control units, and room thermostats.
Details nominal power, voltage range, and approved cable types for operation.
Explains thermal contacts, engine protection, and how to check fan rotation direction.
Shows wiring for triangular (high speed) and star (low speed) circuits for rotation control.
Units FBA-K Ultra 630, 730, 830 are suitable for cooling and include drip tray/pump.
Lists technical specifications for the condensate pump, including flow rate and power.
Wiring diagrams for connecting the condensate pump with isolator switches for Engine 001.
The FBA Ultra must be installed horizontally or with a slight slope for the condensate pump.
Check condensate pump operation by pouring distilled water into the tray after cleaning.
Guidelines for regular inspection, filter cleaning, and removal of deposits for pump operation.
Details warranty terms and the importance of regular maintenance for coverage.
The engine is maintenance-free but requires occasional drying and dust removal.
Instructions for cleaning the heat exchanger using compressed air, detergents, or steam.
Guidance on cleaning and replacing the air filter, specifying P3-class filters.
Procedures for safely shutting down valves, pumps, and circulation before disassembly.
Step-by-step guide to safely disassemble the standard Tanner FBA unit.
Detailed instructions for disassembling the Tanner FBA Ultra model.
Steps to disassemble the FBA-K Ultra unit, covering power, heating, and components.
Procedures for safe removal, fluid draining, and environmentally friendly disposal by professionals.