7
Intended Use of the Product
• ThissignalisforinstallationonH0digitalmodelrailroad
layouts.
• Thissignalmayonlybeusedforanalogoperationwiththe
72760controlbox.
• Useonlyinenclosedareas.
Contents as Delivered
1 Signal
1 Cable with plug, 2-conductor, red and brown
1 Cable with plug, 3-conductor, red and red
1 Cable with plug, 3-conductor, violet, red-braun, red-green
2 Mounting brackets for below-baseboard installation
1 Mounting for C Track
4 Insulator sleeves (red) for C track (1 sprue)
2 Center conductor insulators (gray) for K Track
1 Center conductor connector for K Track
Installation instructions with a template for below-baseboard
installation
Warranty card
Additionaltoolsrequiredforbelow-baseboardinstallation:
screwdriver,4eachcountersunkscrewsØ2.5mmx(length
dependentontheinstallationdepth),drillsØ16mmand2mm.
Safety Notes
• IMPORTANT! The product has sharp edges and points due to
thewayitworks.
• Dowiringandinstallationworkonlywhenthereisnovoltage
present.Failuretoadheretothismaycauselife-threatening
currentandinjury.
• This signal is to be operated only with the permissible
voltage (seetechnicaldata).
Important Notes
• Theoperatinginstructionsareacomponentpartofthe
product and must therefore be kept in a safe place as well as
fortransferoftheproducttothirdparties.
• PleaseseeyourauthorizedMärklinspecialtydealerforrepairs.
• Disposingoftheproduct:www.maerklin.com/en/imprint.html
Technical Data
• Load 100 milliamps
• Loadatthetrackoutputmax.2amps
• Electricalstrengthmax.40volts
Functions
• Capableofmulti-protocols:fx(MM),mfx*,andDCC
• ModeofoperationsetbymeansofDIPswitches
• AddressescanbesetbymeansofDIPswitches:
1-256 fx (MM) (Control Unit 6021)
1-320 fx (MM) (Central Station 6021x/Mobile Station 60653)
1-511 (DCC)
•ProgrammableaddressesbymeansofCVs+1-2,040 DCC
•CharacteristicscanbechangedbymeansofCVs
•Powersuppliedbymeansofthedigitalcurrentcircuit
Signal Installation
Thesignalmustbeprogrammedbeforeactuallyinstallingit.
The following work steps may be done only when there is no
voltage present:
*mfxnotuntilCS2SoftwareVersion4.0