EasyManua.ls Logo

Marktrace MR6100 Series - Page 26

Marktrace MR6100 Series
37 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MR6100 Serial UHF reader user manualVer 1.0)◣
Address
Floor 3/5, Block D,Changyuan New Material Port, No 2 Central 1st Hi-tech Av., Nanshan Shenzhen, P.
R.C. Post518057
Phone0755-2654 6392 FAX0755-2655 3743
E-mailtechnical@marktrace.com Websitewww.marktrace.com
26
with the EPC Gen2 Protocol, RESERVE Membank‟s data is invalid for the tag
filter rule setting. Please 1) select the EPC tag Membank, 2) the word addr. 3)
Word Length, 4) Input the value, then Click „Config‟ ICON for the Tag filter rule
setting.
1Only on Favor quantity working mode, the Tag filter setting is valid, on Favor
speed working mode, tag filter setting is invalid.
2Match setting, reader reads and displays only the condition matched tag.
3Mismatch setting, Reader doesn‟t read and display the condition matched
tag.
4Empty the input value for cancel the Tag filter rule.
5If setting EPC Membank as the Tag filter rule, the valid Word Addr is 2.
6After set the EPC tag filter rule, this rule is valid for all EPC tag detect.
7After set the EPC tag filter rule, this rule is valid for all the time unless the
reader is power off or reset.
6.1.4 EPC Gen2 Tag Lock
1On Gen2 EPC Single Tag interface‟s Gen2 Secured Lock menu for the EPC
Gen2 Tag Lock setting. With Access Password, it can lock Reserve Membank,
EPC Membank, and USER Membank in different lock level. Take below image
for the reference.