5. HT FUSE
The panel mounted fuse holder allows
access to replace blown fuses. If necessary
the HT fuse will blow to protect the
internal circuitry. This can sometimes
happen in the event of output valve
failure.
Note: replace the fuse only with the
value shown on the rear panel. Before
attempting to change the fuse you must
always rst switch the amp off and
disconnect it from the mains electricity
supply. If in doubt, contact your Marshall
dealer.
6. MAINS INPUT
Connects the amp to the mains power
supply.
Note: the mains input socket has an
integrated fuse compartment. Ensure
that the value of a replacement fuse
matches the labelling on the amp rear
panel. You must always rst switch off
and disconnect from the mains electricity
supply before attempting to access the
fuse compartment. If in doubt, contact
your Marshall dealer.
2525C (HEAD SHOWN ON PREVIOUS PAGE)
ENGLISH
4.0
REAR PANEL FUNCTIONS CONTINUED
RETURN SEND
1 x 16 OHM
LOUDSPEAKERS
FX LOOP
1 x 8 OHM
2 x 16 OHM
1 x 4 OHM
2 x 8 OHM
FOOTSWITCH D.I.
MAINS INPUT
HT FUSE
T315mAE250V
PANL-00372 Iss A
230V ~ 50Hz
100 WATTS
FUSE
230V - T1AE250V
100-130V - T2AE250V
123456