© Martin Engineering GmbH 35 M3625UK-10/15
Maintenance
6.3 Regular maintenance
NOTE
If any noises occur or there is any other unusual response of the
guiding station, this must be put out of operation immediately. It
should be put into operation until this problem has been resolved
completely, since otherwise personal injuries or serious damage to
property may occur.
Interval Maintenance part Measure
daily Guide and deflection rollers Visual inspection of the rollers/
replacement
weekly Conveyor belt centring
system
Cleaning
after 30,000 hours of
operation (Power on
hours)
Bearings and rollers Replace
weekly Warning sticker Visual inspection of all warning
stickers / Clean all warning
stickers. Replace any warning
labels which are illegible. Warning
labels may be purchased from
Martin Engineering or an
authorised dealer
Refer to the
manufacturer's
documentation
Support roller Replace
Tab. 2: Maintenance table