MODELS:
MAA1018A-MAA1060A, MGA1072A
(Single Stage)
MAA2060A-MAA2072A, MGA2072A
(2-Stage)
Installation & Operation Manual
10 & 11 EER Vertical Wall-Mount Air Conditioners
Manufactured By:
Marvair, An AirX Climate Solutions Brand
P.O. Box 400 • Cordele, Georgia 31010 • 156 Seedling Drive • Cordele, Georgia 31015
(229) 273-3636 • Fax (229) 273-5154
E-mail: marvairsales@airxcs.com • Internet: www.Marvair.com
The most current version of this manual can be found at www.Marvair.com.
IMPORTANT
This manual may include information for options and features which may not be
included on the unit being installed. Refer to the unit data label or Model Identication
to determine which features and options this unit is equipped with.
INSTALLER: Afx the instructions on the inside of the building adjacent to the thermostat.
END USER: Retain this manual for future reference.
Marvair MAA/MGA Wall Mount AC Installation & Operation Manual
12/2021 Rev.16
Air Conditioner Product Manual
Vertical Wall-Mount Air Conditioners
with Front Control Box Panel

Table of Contents

Questions and Answers

  • T
    Tony ThompsonAug 9, 2025
    Why does my Marvair Air Conditioner blow fuses or trip the circuit breaker?
    • E
      edwardsmirandaAug 9, 2025
      Your Marvair Air Conditioner might be blowing fuses or tripping the circuit breaker due to several reasons: * Inadequate circuit ampacity: Refer to electrical requirements and correct as necessary. * Short, loose, or improper connection in field wiring: Check field wiring for errors. * Internal short circuit, loose or improper connection(s) in unit: Check wiring in the unit, see wiring and schematic diagrams, and test components (especially the compressor) for shorts. * Excessively high or low supply voltage or phase loss: Note voltage range limitations specific to the compressor troubleshooting section.
  • S
    steven93Aug 14, 2025
    Why is my Marvair Air Conditioner running continuously but cooling is insufficient?
    • M
      Michael BowersAug 15, 2025
      There are several reasons why your Marvair Air Conditioner might be running for long periods or continuously while providing insufficient cooling: * Dirty filter or reduced airflow: Check air filters and blower operation. Remove any airflow restrictions. * Low refrigerant: Check for proper refrigerant charge and possible leaks. * Component failure: Inspect internal components, especially the compressor, for proper operation. * Unit undersized for the job: Consider adding additional units for greater capacity.
  • W
    Wendy JonesAug 19, 2025
    What to do if there is water on the floor near my Marvair Air Conditioner?
    • H
      heatheredwardsSep 12, 2025
      If you find water on the floor near your Marvair Air Conditioner, here's what you should check: * Obstruction in condensate line: Look for any clogs or restrictions. * Obstruction or leak in condensate pan: Inspect the pan for leaks or blockages. * Unit is not level: Ensure the unit is properly leveled.
  • J
    James TranAug 25, 2025
    What to do if my Marvair Air Conditioner unit cycles on high or low pressure limit?
    • N
      Nicholas MoonAug 26, 2025
      If your Marvair Air Conditioner cycles on high/low pressure limit, consider the following: * Loss or restriction of airflow: Check the blower assembly for proper operation and look for airflow restrictions, such as a dirty air filter. Also, check the blower motor and condenser fan. * Restriction in refrigerant circuit: Check for blockages or restrictions, especially in the filter drier and capillary tube assembly. * Refrigerant overcharge: Evacuate and recharge the system to factory specifications. * Defective pressure control: Check the limit cutout pressures. The control should actuate at approximately 60 PSIG (low pressure) and 650 PSIG (high pressure).
  • B
    Brandon WoodardAug 29, 2025
    How to troubleshoot no space heating or reduced heating in Marvair Air Conditioner?
    • M
      Michael ThompsonAug 30, 2025
      If your Marvair Air Conditioner (equipped with resistance elements) has no or reduced space heating, it could be due to: * Defective heating element(s): Check the resistance element(s) for continuity. * Thermal limit open: Check continuity across the thermal limit switch. * Defective heater contactor: Check the relay for proper operation and replace it if defective.
  • G
    Gary OlsonSep 4, 2025
    How to fix a Marvair Air Conditioner that does not run?
    • L
      Lisa PattersonSep 4, 2025
      If your Marvair Air Conditioner isn't running, here are some potential causes and solutions: * Power supply problem: Check the power supply for adequate phase and voltage, the wiring to the unit, and external breakers or fuses. * Tripped internal disconnect: Check internal circuit protection devices for continuity. * Shut off by external thermostat or defective thermostat: Check the operation of the wall-mounted thermostat. * Unit off on high or low pressure limit: Reset the pressure switch. * Internal component or connection failure: Check for loose wiring and component failures.