EasyManua.ls Logo

MAS Vector Compact 10K - Condensate Drains

Default Icon
37 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8/8/2014 VECTOR COMPACT
file:///C:/Users/E139344/Documents/Miscellaneous/Manuals,%20etc/Rinker/VECTOR%20COMPACT.htm 8/37
CONDENSATE DRAINS
The condensate drain pan is 2² high with two drain locations. During conditions of high humidity, condensate may be produced
at a rate of up to two gallons per hour. With this in mind, it is important to route condensate drains downward to a sump pump.
Do not route condensate drains to the bilge. After the condensate drain installation is complete, test the installation by pouring a
quart of water into the pan and checking for good flow. See note below.
For installation of the condensate drain:
1. Remove the aft facing watertight plug from the base pan of the a/c unit.