lightingagain.Ifyouneedtopresstheresetagain,waitatleasttensecondsbeforedoingthis.Ifthereisa
lotofairinthepipeline,itmaybenecessarytorepeatthisresetprocedureseveraltimes.
•Whenthepilotlights,theECSsystemshutsdowntheignitionsparkandthenturnsonthegassupplytothe
mainburner.Thiswilligniteshortlyafter.
•Oncethemainburnerisalight,thesizeoftheflamecanbeadjustedusingthetoprockerswitchonthe
handpiece. Pressing+ increasestheflame. Note that theresponseto flame adjustment may take about
twentyseconds,sotherockerswitchshouldbehelddownuntiltheflamereachesthedesiredheight.
•Whiletheheaterisbeingswitchedonandoffbythewallthermostat(iffitted),theredindicatorlightbeside
thereceiverwillremainalight,showingthattheheaterisreadytolightagainwhentheroomtemperature
falls. The flame will light at its last height setting. The pilot light extinguishes each time the flame
extinguishes.
•Ifthemainssupplytotheheaterisswitchedoff,thefirewilllightnexttimeattheLOWflamesetting,butif
themainssupplyisuninterrupted,theflamewilllightagainatitslastsetting.
•Thelowerrockerswitchonthehandpiececontrolsthefan,switchingitto‘OFF’,‘LOW’,‘MEDIUM’and
‘HIGH’sequentially.NOTE.Thefanisalsocontrolledbyaninternalswitchwhichwillnotpermititto
startuntilthefireishot(abouttenminutesfromcoldonhighfire)andwillkeepitrunningafterthefire
goesout.Thehandpiecewillnotstartthefanduringthewarm-upperiod,butitcanpre-selectthespeedat
whichthefanwillstartoncethefireboxishot.
NOTE:Occasionallytheelectricalsystemmay‘lockup’.Turningoffthemainssupplyfortensecondswill
clearthis.
TURNINGTHEFIREOFF:-
ALLMODELSEXCEPTECS:-
•Pushdownandturnthecontroltothe‘PILOT’position.Alternatively,modelsfittedwithwallmountedor
portablethermostatsmaybeshutdownatthethermostat.Thepilotwillremainalight.
•Ifthefanisrunning,turnitoffeitherattherotaryswitchorthewallsocket.(STDmodelsonly).Models
fittedwithinternalswitcheswillstopafterthefireboxhascooled.
•ToextinguishthepilotlightonSTDmodels,pressdownonthecontrolandturnitfullyclockwisetothe
‘OFF’position.ToextinguishthepilotlightonACCandRMTmodels,pressthePILOTcontrolknobpart
waydownandturnitfullyclockwise.
ECSMODELS:-
•Tostopthefireimmediately,presstheTOPbuttononthehandpieceonceorpressthesmallbuttonbythe
receiver(onthepedestalfoot)once.Theindicatorlightbythereceiverwillextinguish,thefireandpilot
lightwillshutdownandthefanwillstop.Alternatively,turningoffthemainsplugswitchormovingthe
slideswitchonthewallthermostatawayfrom‘HEAT’willextinguishthefire.
•To stop thefire after a delay ofabout 30 minutes, press the BOTTOM button on the handpiece. The
indicatorlightbesidethereceiverwillstartflashingand eventuallythe firewillshutdown.Pressingthe
delayedstopbuttonagainduringtheshuttingdownperiodwillrestoretheheatertonormalcontinuous
operation.
RECEIVERSWITCHPOSITIONS(ACCandRMTmodels)
Thereceiverswitchhasthreepositions,‘OFF’,‘ON’and‘REMOTE’.
‘OFF’preventsthemainburnerfrombeinglit.Thisisausefulsafetyfeatureifchildrenmightplaywiththe
remotecontrol.
‘ON’bypassestheremotecontrolentirely,allowingtheheatertobeliteventhoughthebatteriesinthereceiver
orremotecontrolaredead,or,inthecaseoftheRMTmodel,ifthemainspowersupplyhasfailed.Inthis
settingthethermostatisinactiveandtheheatoutputisfixedonLOWforRMTmodels.Itmaybecontrolled
manuallyonallothermodels.
‘REMOTE’bringstheremotecontrolintofulloperation,allowingitsin-builtthermostattomatchheatoutput
totheheatingneedsoftheareatheremotecontrolisin,providedthattheremotecontrolisleftpointingtoward
theheater.ForautomaticheatcontrolwithRMTmodels,theremotecontrolmustbe ‘ON’ inthe‘AUTO’
mode.Theremotecontrolcanbesettoautomaticallyruntheheaterwithinanydesiredtimeperiod.Seethe
separateremotecontroloperatinginstructionsforfulldetails.