EasyManua.ls Logo

Masport BALTIMORE STD NG - Page 7

Masport BALTIMORE STD NG
20 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
lightingagain.Ifyouneedtopresstheresetagain,waitatleasttensecondsbeforedoingthis.Ifthereisa
lotofairinthepipeline,itmaybenecessarytorepeatthisresetprocedureseveraltimes.
•Whenthepilotlights,theECSsystemshutsdowntheignitionsparkandthenturnsonthegassupplytothe
mainburner.Thiswilligniteshortlyafter.
•Oncethemainburnerisalight,thesizeoftheflamecanbeadjustedusingthetoprockerswitchonthe
handpiece. Pressing+ increasestheflame. Note that theresponseto flame adjustment may take about
twentyseconds,sotherockerswitchshouldbehelddownuntiltheflamereachesthedesiredheight.
•Whiletheheaterisbeingswitchedonandoffbythewallthermostat(iffitted),theredindicatorlightbeside
thereceiverwillremainalight,showingthattheheaterisreadytolightagainwhentheroomtemperature
falls. The flame will light at its last height setting. The pilot light extinguishes each time the flame
extinguishes.
•Ifthemainssupplytotheheaterisswitchedoff,thefirewilllightnexttimeattheLOWflamesetting,butif
themainssupplyisuninterrupted,theflamewilllightagainatitslastsetting.
•Thelowerrockerswitchonthehandpiececontrolsthefan,switchingitto‘OFF’,‘LOW’,‘MEDIUM’and
‘HIGH’sequentially.NOTE.Thefanisalsocontrolledbyaninternalswitchwhichwillnotpermititto
startuntilthefireishot(abouttenminutesfromcoldonhighfire)andwillkeepitrunningafterthefire
goesout.Thehandpiecewillnotstartthefanduringthewarm-upperiod,butitcanpre-selectthespeedat
whichthefanwillstartoncethefireboxishot.
NOTE:Occasionallytheelectricalsystemmay‘lockup’.Turningoffthemainssupplyfortensecondswill
clearthis.
TURNINGTHEFIREOFF:-
ALLMODELSEXCEPTECS:-
•Pushdownandturnthecontroltothe‘PILOT’position.Alternatively,modelsfittedwithwallmountedor
portablethermostatsmaybeshutdownatthethermostat.Thepilotwillremainalight.
•Ifthefanisrunning,turnitoffeitherattherotaryswitchorthewallsocket.(STDmodelsonly).Models
fittedwithinternalswitcheswillstopafterthefireboxhascooled.
•ToextinguishthepilotlightonSTDmodels,pressdownonthecontrolandturnitfullyclockwisetothe
‘OFF’position.ToextinguishthepilotlightonACCandRMTmodels,pressthePILOTcontrolknobpart
waydownandturnitfullyclockwise.
ECSMODELS:-
•Tostopthefireimmediately,presstheTOPbuttononthehandpieceonceorpressthesmallbuttonbythe
receiver(onthepedestalfoot)once.Theindicatorlightbythereceiverwillextinguish,thefireandpilot
lightwillshutdownandthefanwillstop.Alternatively,turningoffthemainsplugswitchormovingthe
slideswitchonthewallthermostatawayfrom‘HEAT’willextinguishthefire.
•To stop thefire after a delay ofabout 30 minutes, press the BOTTOM button on the handpiece. The
indicatorlightbesidethereceiverwillstartflashingand eventuallythe firewillshutdown.Pressingthe
delayedstopbuttonagainduringtheshuttingdownperiodwillrestoretheheatertonormalcontinuous
operation.
RECEIVERSWITCHPOSITIONS(ACCandRMTmodels)
Thereceiverswitchhasthreepositions,‘OFF’,‘ON’and‘REMOTE’.
‘OFF’preventsthemainburnerfrombeinglit.Thisisausefulsafetyfeatureifchildrenmightplaywiththe
remotecontrol.
‘ON’bypassestheremotecontrolentirely,allowingtheheatertobeliteventhoughthebatteriesinthereceiver
orremotecontrolaredead,or,inthecaseoftheRMTmodel,ifthemainspowersupplyhasfailed.Inthis
settingthethermostatisinactiveandtheheatoutputisfixedonLOWforRMTmodels.Itmaybecontrolled
manuallyonallothermodels.
‘REMOTE’bringstheremotecontrolintofulloperation,allowingitsin-builtthermostattomatchheatoutput
totheheatingneedsoftheareatheremotecontrolisin,providedthattheremotecontrolisleftpointingtoward
theheater.ForautomaticheatcontrolwithRMTmodels,theremotecontrolmustbe ‘ON’ inthe‘AUTO’
mode.Theremotecontrolcanbesettoautomaticallyruntheheaterwithinanydesiredtimeperiod.Seethe
separateremotecontroloperatinginstructionsforfulldetails.
5