Recommended System Components
Primary Shut-Off Trap:
A float ball shut-off that prevents liquid in the tank from overflowing into the system and entering the
pump. Liquid entering the pump can damage or destroy the pump.
Secondary Moisture Trap (Scrubber):
Removes liquid still in the air steam after passing through the Primary Trap. The Scrubber should be
drained after every load.
Inlet Filter:
Prevents small particulate matter from entering the pump. This filter should be checked and
cleaned, or replaced regularly.