3
Logix Control Valve:
1. When facing the front of the Logix timer, the inlet connection
(
Figure 1) is located on the left and the outlet connection is on the
right. The control valve's inlet and outlet connections are either
1” copper or pvc equipped with gasket and nut.
Figure 1
Install the 268 bypass valve (See Figure 2) with inlet and outlet
handles facing upward. Place gasket into nut and secure 1” copper
or pvc tail piece with a nut. Repeat the procedure for the outlet
connection.
DO NOT OVERTIGHTEN THE NUT.
Figure 2
2. The control valve's drain connection is 3/4" npt and is located on
the back of the control valve.
3. Turn the control valve upside down and ensure that the control
valve distributor o'rings are in place. Use silicone lubricant on
the o'rings.
4. Place the control valve onto the distributor pipe.
5. Thread the control valve hand tight to 20 foot pounds!
DO NOT OVERTIGHTEN!
**DO NOT USE PETROLEUM!**
**USE ONLY SILICONE **