10
Apply solution underneath regulator
orice connection.
Apply solution to regulator orice location.
Failed test will present bubbles
as shown below.
Apply solution to gas
cylinder and regulator
connection.
DURINGANYPORTIONOFSOAPYWATERTESTIFBUBBLESCONTINUETO
APPEAR,STOP,DONOTUSEUNIT.CONTACTLOCALPROPANEDEALERORMASTERBUILT
CUSTOMERSERVICEAT1-800-489-1581.
Note: Use 1LB (0.45kgs) gas cylinder with this unit. May use 20LB (9kgs) gas cylinder that has a
protective collar with 20LB (9kgs) adapter hose.
Cylinder and adapter hose NOT included with this unit.
Apply solution to gas
cylinder, regulator
connection, and the
entire length of the
hose.
SOAPY WATER TEST WARNINGS & PROCEDURES