MAINTENANCE
23
AIR-POWERED CLIPPED-HEAD FRAMING NAILER 058-8434-4
Maintenance
DANGER!
Potential hazard that will result in serious injury or loss of life.
Disconnect the tool from the air compressor before performing maintenance/
service, adjusting, clearing jams, reloading, and when it is not in use.
Repairs must be performed by a qualified service technician only. Failure to
comply will lead to serious injury or loss of life.
MAINTENANCE
R
EQUIRED
DESCRIPTION
TOOLS OR
M
ATERIALS
R
EQUIRED
MAXIMUM SERVICE INTERVAL
Each Use or
e
very 2 Hrs
Monthly
As
N
eeded
General inspection -
free movement
Trigger, spring,
safety mechanism
None X
In-depth inspection
Worn or broken
parts
X X
Replace worn or
broken parts
X
Lubrication See below
Pneumatic tool
oil
X
Lubrication: If the Air-powered Clipped-head
Framing Nailer and the compressor are not
equipped with an in-line lubrication system, place
up to 6 drops of pneumatic tool oil into the air inlet
before each work day or after every 2 hours of
continuous use, depending on the characteristics
of the workpiece and type of nails used.