Malfunction Possible cause What to do
High ambient
temperature
Nothing; if ambient temperature is more
than the setting limit, the charge current is
automatically reduced.
Batteries not fully
charged
See “Charge current too low” in this table.
Reduce load taken from the batteries.
Use a battery charger with higher capacity.
Use the battery temperature sensor.
Check battery and replace if necessary.
Batteries are
discharged too fast
Battery capacity reduced
due to wastage or
sulphation, stagnation
Charge and recharge a few times, this
might help.
Check battery and replace if necessary.
Check battery and replace if necessary.
Use the battery temperature sensor.
Check the MasterBus cables.
placed at the ends of the
network.
MasterBus needs a terminating device on
both ends of the network. Check if
connected.
configured as a ring
network.
Ring networks are not allowed. Check the
connections of the network.