OPERATION
18 Copyright © 2009 Mastervolt / December 2009 / WHISPER 3.5 / EN
3 OPERATION
3.1 GENERAL
The generating set is operational after full installation and
filling up with: fuel, engine lubricating oil and cooling liquid,
filling the starter battery with acid, connecting the battery
to earth and connecting the MasterView Easy remote
panel.
1 Filling cap
2 Minimum oil level
3 Maximum oil level
Figure 9
3.2 OPERATING INSTRUCTIONS
3.2.1 Summarised operating instructions (daily
use)
Routine "pre-start" checks:
1 Check oil level (refer to figure 9).
2 Engine cooling system (all valves open).
3 Power source selector switch (off/shore
power/generator power). Switch power source switch
to "OFF", or switch off all consumers in the usual way.
If a Mass SystemSwitch is installed, this operates
automatically.
4 Switch on battery switch (when installed).
5 Fuel valve: open.
Starting:
To initiate the full automatic starting procedure, push
the Start / Stop button on the Local control panel or
give a start command by means of the MasterView
Easy. You can monitor the procedure on the display
of the MasterView Easy
In operation checks:
1 Check for abnormal noise or vibration;
2 Check the voltage;
3 Check sea water flow at exhaust outlet;
4 Power source selector switch (off/shore
power/generator power). Switch to power source
Generator. If a Mass SystemSwitch is installed, this
operates automatically;
5 Before loading the generating set up to maximum,
have it run warm. Continuous load should be
restricted to 70 % of maximum load.
Stopping generator:
1 Switch off all electrical devices (consumers). If the
generating set has been running under full load for a
longer period, do not shut it down abruptly. Reduce
the electrical load to about 30% of the rated load (i.e.
30% of 3 kW is approx. 1000W) and let it run for
approx. 5 minutes.
2 Push the Start / Stop button on the Local control panel
or give a stop command by means of the MasterView
Easy.
3 Close the inlet sea water cock.
4 Switch to an other 230V power source, if available. If
a Mass SystemSwitch is installed, this is done
automatically.