CHAPTER 5:  mX-t5X overlay Description / programing / engineering moDe 
12
5.7 MANAGER SCREENS EXCEPTIONS/DETAILS
Below is a list of functions for each Manager Setting. Exceptions will be noted in 
the description for each manager setting:
P0  MAXIMUM TIME 
(EDIT)
    This variable controls the program maximum time.   
    Active variable display in the time seven segment display. 
    Numeric entry is active.
P1  DEFAULT TIME 
(EDIT)
    This variable controls the default program time.    
    Active variable displayed in the time seven segment display. 
    Numeric entry is active.
P2  DEFAULT LEvEL 
(EDIT)
    This variable controls the default program level (may be eliminated in final product).     
    Active variable displayed in the time seven segment display. 
    Numeric entry is active.
P3  DEFAULT AGE 
(EDIT)
    The variable controls the default users age used in the goal heart rate calculations.    
    Active variable displayed in the time seven segment display. 
    Numeric entry is active.
P4  DEFAULT WEIGHT 
(EDIT)
    This variable controls the default users age used in the calorie calculations.    
    Active variable displayed in the time seven segment display. 
    Displayed in native unites (kilogram or pounds)
    Numeric entry is active.
P5  ACCUMULATED DISTANCE
    This variable displayed in the time seven segment disply.   
    Accumulated distance is not editable, for display only. 
    Displayed in native unites (kilometers or miles)
    Holding the start key resets the accumulated distance.
P6  ACCUMULATED TIME
    This variable displayed in the time seven segment disply.   
    Accumulated time is not editable, for display only. 
    Holding the start key resets the accumulated distance.
P7  SOFTWARE vERSION
    Active variable displayed in the time seven segment display.   
    Accumulated distance is not editable, for display only.
P8  START SPEED 
(EDIT)
    Controls the starting speed for all programs (minimum speed not affected).    
    Active variable displayed in the time seven segment display.
    Displayed in native unites (kilometers per hour or miles per hour).
    Reverts to default value on unit change. 
    Numeric entry is active.
P9  MAXIMUM SPEED 
(EDIT)
    Controls the maximum speed for all programs.   
    Active variable displayed in the time seven segment display.
    Displayed in native unites (kilometers per hour or miles per hour)
    Reverts to default value on unit change. 
    Numeric entry is active.
5.6 ENGINEERING MODE
Manager  screens  allow  the  viewing  and  editing  of  variables  that  would  be 
necessary for a club operator/manager to customize. Unless otherwise noted 
manager screens consist of the initial screen, the editing or action screen and 
the  saving  screen. The  initial  screen  displays  the variable  type  and  in  most 
cases the current value. Edit or actions screens are where the editing of the 
variable take place. The saving screen indicates the variable is being saved.
To  access  the Manager  Settings  press and  hold the  ELEvATION  DOWN and 
SPEED UP bottons for three seconds.
Use  the  ELEvATION  or 
SPEED  UP  and  DOWN  arrows  to  scroll  through  the 
different manager setting.
Press 
SELECT to edit the selected manager setting.
Use the ELEvATION or SPEED UP and DOWN arrows to set the variable.
Press 
START to save the seected variable.
NOTE: SAvING all appear in the 7 segment window when the variavle is being 
saved to memeory.