Display of number of operating hours of face lamps
Press button (B). The LED of button (D) will start to ! ash, and the display will show the number of hours
for which the face lamps have operated (up to a maximum of 9999).
Display of number of operating hours of body lamps
Press button (B) again. The LED of button (E) will start to ! ash, and the display will show the number of
hours for which the body lamps have operated (up to a maximum of 9999).
Display of operating hours accumulated for replacement of face lamps
Press button (B) again. The LED of button (H) will start to ! ash, and the display will show the number of
operating hours accumulated for the replacement of the face lamps (shown on the 4-! gure display up to a
maximum of 1000). When the hours shown on the 4-! gure display exceed the preset time the LED corre-
sponding to the selection of the face lamps (LED of button F) will start to " ash.
Display of operating hours accumulated for replacement of body lamps
Press button (B) again. The LED of button (I) will start to ! ash, and the display will show the number of
operating hours accumulated for the replacement of the body lamps (shown on the 4-! gure display up to a
maximum of 1000). When the hours shown on the 4-! gure display exceed the preset time the LED corre-
sponding to the selection of the body lamps (LED of button G) will start to " ash.
Display of operating hours accumulated for periodic maintenance
Press button (B) again. The LED of button (A) will start to ! ash, and the display will show the number of
operating hours accumulated for periodic maintenance (shown on the 4-! gure display up to a maximum of
1000). When the hours shown on the 4-! gure display exceed the preset time the LED R corresponding to
the periodic maintenance symbol will start to " ash.
End of programming phase
Press button (B) again to close the programming phase. The machine will be set for a new operating cycle.
USE OF TANNING LAMP FUNCTIONS (FACE/BODY IF POSSIBLE TO SELECT )
This function must be enabled only before the session is started.
The buttons used for selecting face and body lamps are F (BODY) and G (FACE), with indicator LEDs, and
the key selector (T).
In stand-by status the panel shows the last selection made. In default status both the face and body functions
are selected.
Proceed as follows to set functions:
1- Press both buttons F-G. If the message SEL appears on the display proceed with selection. If the message
BLOC appears, turn the mechanical key (T) until the message SEL appears.
2- Use buttons F-G to select the new setting desired.
3- To lock the new selection for all subsequent selections, turn the mechanical key and check that the message
SEL changes to BLOC.
4- Finally press stop button (B) to exit from the selection program.
5- From point 2 — If the new selection is to be used without locking selection with the mechanical key, press
stop button (B) to exit from the selection program.
6- From the moment buttons (F-G) are pressed there are 30 seconds available for making changes. Several
changes can be made, but only the ! nal setting is memorized.
ONLY FOR INFORMATION